Engineering Structures


Seismic monitoring of engineering structures e.g. Dam walls

seismic controller sensors sensors gs gs sensors sensors

Operation

A network of independent GS data acquisition units independently records the response of the dam wall to natural and induced seismicity for later analysis on the seismic controller. The seismic controller is also used for the occasional field-configuration of the GS units.

Communications

Use of common cellular telephone modems here minimises infrastructural set-up costs. At midnight every day all seismic stations are contacted and seismic information downloaded. Seismograms of common events are post-associated for off-line processing and interpretation.

Seismic Sensors

Each GS data acquisition unit can monitor and pre-process up to six seismic signals, in any combination of uni-, bi- or tri-axial seismic sensors. For each seismic channel up to 3 logical channels may be extracted with GS technology. Both geophones and accelerometers (piezoelectric and Force-Balance) are currently supported.

Seismic Data Processing & Interpretation

The seismograms of every seismic event that triggers multiple stations are post-associated on the seismic controller. Seismograms are then exported to ASCII format for processing with an engineering structural response package.

 